1. Home
  2. Knowledge Base
  3. POS Peripherals
  4. Datalogic Factory Setup Guide

If your Datalogic DL-Axist inventory scanner gets reset back to manufacturer’s settings or is a brand new device out of the box, then you will need to setup the device to work with WooPOS Count app. Please follow the instructions below for device configurations and installation.

Scanner Wedge Settings

The DL-AXIST scanner can have some settings managed to assist your scan results.  To access these controls you can navigate to the settings app on the device.

1.png

 

You may need to open the app drawer by clicking on the 2.PNG  or Capture.PNG button and navigating through the available apps to find settings.  Depending on the version of operating system on the scanner the settings icon may be different.

Navigate down the list of features in the settings application until you can select the Scanner settings.

3.png

 

There are 3 different scanner settings to consider managing.

4.png

 

 1.  Choose this option to enable the keyboard wedge.

This needs to be enabled so that scanned results will populate in WooPOS Count app or any other text field in the scanner.  Make sure that the check boxes shown below are enabled.

 

2.  Good Read settings influence the indication of a successful barcode scan performed by the scanner.  Adjust these settings by enabling or disabling the check boxes shown below.

6.png

 

3.  Additional notification controls are available here to adjust how the Good Read results are displayed or heard.

7.png

 

Test scanning with the barcode device to preview the results of the adjustments made.

 

 

Enable Symbology Checksum

If you are having issues with the check-digit not being scanned at the end of a barcode then you will need to enable a setting to include this character in the scan result.  Navigate through settings until you find Scanner Settings to select.

Screenshot_2000-01-01-00-08-19.png

 

Navigate to open Symbology Settings.

Screenshot_2000-01-01-00-08-25.png

UPC-A

Navigate and select the settings option for UPC-A

Screenshot_2000-01-01-00-08-34.png

 

To Enable Leading Digit or Check Digit on a UPC code check the settings below.

A checksum is Check Digit(Last Digit) at the end of a UPC code. 059200708124

System Digit is Leading Digit(First Digit) at the front of a UPC Code.  059200708124

Screenshot_2000-01-01-00-08-41.png

EAN-13

Navigate and select the settings option for EAN-13.

Screenshot_2000-01-07-23-18-38.png

 

Enable the setting for checksum as shown below.

Screenshot_2000-01-07-23-18-43.png

Now when you scan a UPC-A or EAN barcodes you will notice the additional character added to the scanned result.

 

More settings:

Adjust Softspot scanning options

Connect Scanner to Computer

 